Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

INDIANFIRE 61f008ed5a7b9500015432d7 Products https://indianfire.nowfloats.com
  • 2022-06-02T05:34:50

FIRE ALARM SYSTEM We design and install the system as per the customer’s requirement. The above items are available in different makes namely - System Sensor, Apollo, Ravel, Morley, BOSCH etc. In case of fire early detection of smoke and heat helps in fighting the fire effectively & amp; extinguishing it in nascent stage. Thus preventing the fire from spreading and saving life and loss of property and business. AUTOMATIC FIRE DETECTION & amp; ALARM SYSTEM In case of fire early detection of smoke and heat helps in fighting the fire effectively & amp; extinguishing it in nascent stage. Thus preventing the fire from spreading and saving life and loss of property and business. It is a basic conventional system in which Fire Alarm Panel indicates the zone which has caught fire. The system consists of following components • Fire Alarm Panel Starts from 2 zone, up to 24 zones • Detectors • Optical Smoke Detector • Heat Detector • Flame Sensor • Beam Detector • Intrinsically safe Ionization Detector • Intrinsically safe Thermal Detector • Manual Call Point • Hooter • Response Indicator • Cabling We design and install the system as per the customer’s requirement. The above items are available in different makes namely - System Sensor, Apollo, Ravel, Morley, BOSCH etc. Intelligent Addressable Fire Alarm System This is advanced system in which control panel is capable of not only knowing the detector’s location accurately but also exactly how much smoke is in the chamber of the detector. The system consists of following • Intelligent Fire Alarm Control • Addressable Detectors • Isolator Module • Loop driver card • Communication module • Modbus • Loop Addressable Sounder • Manual Call Point Information on location of the fire, fault and system status can be easily displayed or printed in multiple locations. Integration to voice Evacuation systems, Paging systems and third party control systems is supported through a range of peripheral interface units. Following approved makes are available - Morley –IAS, Notifier, Hochiki, GE Edward, Honeywell, BOSCH, EST, GST. Wireless Fire Alarm System Wireless Fire Alarm System is addressable and requires no cabling to be done and it indicates the accurate location of the detector fired. The system consists of following • Wireless Fire Alarm Panel ( With range of 1-2 Kms., comes in 99 zones and 999 zones with programmable detectors ) • Wireless Detectors • Radio Emitter – to transmit the signal • Wireless Manual Call Point Features • NO wiring and conducting, works on radio waves. Lot of concealed wiring is required in case of wired system. • Each detector works as an independent unit. So in case of non working of particular detector it does not have any effect on the system. But in case of Wired System Complete Zone / system becomes effected due to damaging of wire or failure of connection. • Zero maintenance and no AMC required. Where as AMC is must and tedious job in case of wired system. • Immediate installations, 200 nos. of detectors with panel can be installed in a single day even when building is occupied. Approximately 20 days are required in case of wired system. • Can be installed in running office complex / factory etc. • Complete flexibility. Any time there is a requirement for any modernization of the building. Any detector / panel can be shifted as per requirements. • Very – very competitive prices of Wireless Addressable Fire Alarm Panel. Wired panel with equal no.s of zones cost Five times more than the wireless panel. • Saving of cost from 10% to 60% at the time of installations and 90% saving in running cost. • Easy testing while every time it is practically not possible to test the system by generating smoke. A test button is available with each wireless smoke detectors and just pressing the button is sufficient for working of detector , panel and emitter. • In case of non working / failure of main control panel in wired system, whole system will be held up. But the complete system will be working in case of non working of panel. Information on location of the fire, fault and system status can be easily displayed or printed in multiple locations. Integration to voice Evacuation systems, Paging systems and third party control systems is supported through a range of peripheral interface units. Following approved makes are available - Morley –IAS, Notifier, Hochiki, GE Edward, Honeywell. Aspiration Smoke Detection System The HSSD and VESDA are the internationally approved trade names for ASPIRATION SYSTEM. Aspirating Smoke Detection system (ASD) designed to give very early indication of an incipient fire condition. This pre-emptive warning – before the transition into the flaming and heat stages – provides the time necessary to take corrective action and avoid the danger, damage and disruption to operations that a fire can cause. Aspirating Detection The detector is mounted either inside or outside the area. It draws air from the protected area using an aspirating fan which is housed in the detection unit. The pipe network contains sampling holes at predetermined locations along the pipe network through which the air is LASER DIODE LIGHT SOURCE drawn. Detectors can protect areas up to 2000 square metres to BS5839, or between 500 to 750 square metres to BS6266, in high air flow conditions. The pipework is configured in various ways according to the application. Typically it will comprise a pipe network with sampling points at intervals similar to point detection. It can also, for example, be arranged to monitor across air handling units or in ducts. Sampling pipe hart xl sampling points • Laser based particle counting – the superior technology • Elegant, compact, lightweight design • No particle filters required • No recalibration during lifetime of detector • Complete flexibility – four basic sub units provide installation options • On site sensitivity selection 0.0025%/m to 1%/m • LaserJet networking options • Modular design for fast and easy servicing • Configurable for integral or remote display options • Attachable power supply and battery back up unit • Individual pre-alarm and alarm levels Standalone Smoke Detectors Standalone smoke detectors are used for small areas such as small office, cabins, shops etc. It gives alarm from the unit in case of fire. The system consists of following • Standby Current 10 μA • Alarm Current 30 μAT • Temprature Range 10-50 oC • Alarm Density 0.65-1.55 %FT • Alarm Volume 85dB in 3meter distance • ABS Fire resistance plastic case • Unit Box 10.8x114.4cm 0.20kgs • Carton 65x24x39cm GW - 21.00kgs Beam Detection System Beam detection system is ideal where the area to be protected is large , the height of ceiling is too much and where other smoke / heat detectors will be ineffective to install. Features • Low cost protection of large areas • Very low maintenance • Quick and easy installation • Very minimum cabling required Applications • Auditorium • Multiplex • Historic Building • Warehouse • Airports • Large Storage Areas • Shopping Malls • Hotel Atria • Museums Beam Detector’s available in following brands – System Sensor, Fire Ray.

FIRE ALARM SYSTEM We design and install the system as per the customer’s requirement. The above items are available in different makes namely - System Sensor, Apollo, Ravel, Morley, BOSCH etc. In case of fire early detection of smoke and heat helps in fighting the fire effectively & amp; extinguishing it in nascent stage. Thus preventing the fire from spreading and saving life and loss of property and business. AUTOMATIC FIRE DETECTION & amp; ALARM SYSTEM In case of fire early detection of smoke and heat helps in fighting the fire effectively & amp; extinguishing it in nascent stage. Thus preventing the fire from spreading and saving life and loss of property and business. It is a basic conventional system in which Fire Alarm Panel indicates the zone which has caught fire. The system consists of following components • Fire Alarm Panel Starts from 2 zone, up to 24 zones • Detectors • Optical Smoke Detector • Heat Detector • Flame Sensor • Beam Detector • Intrinsically safe Ionization Detector • Intrinsically safe Thermal Detector • Manual Call Point • Hooter • Response Indicator • Cabling We design and install the system as per the customer’s requirement. The above items are available in different makes namely - System Sensor, Apollo, Ravel, Morley, BOSCH etc. Intelligent Addressable Fire Alarm System This is advanced system in which control panel is capable of not only knowing the detector’s location accurately but also exactly how much smoke is in the chamber of the detector. The system consists of following • Intelligent Fire Alarm Control • Addressable Detectors • Isolator Module • Loop driver card • Communication module • Modbus • Loop Addressable Sounder • Manual Call Point Information on location of the fire, fault and system status can be easily displayed or printed in multiple locations. Integration to voice Evacuation systems, Paging systems and third party control systems is supported through a range of peripheral interface units. Following approved makes are available - Morley –IAS, Notifier, Hochiki, GE Edward, Honeywell, BOSCH, EST, GST. Wireless Fire Alarm System Wireless Fire Alarm System is addressable and requires no cabling to be done and it indicates the accurate location of the detector fired. The system consists of following • Wireless Fire Alarm Panel ( With range of 1-2 Kms., comes in 99 zones and 999 zones with programmable detectors ) • Wireless Detectors • Radio Emitter – to transmit the signal • Wireless Manual Call Point Features • NO wiring and conducting, works on radio waves. Lot of concealed wiring is required in case of wired system. • Each detector works as an independent unit. So in case of non working of particular detector it does not have any effect on the system. But in case of Wired System Complete Zone / system becomes effected due to damaging of wire or failure of connection. • Zero maintenance and no AMC required. Where as AMC is must and tedious job in case of wired system. • Immediate installations, 200 nos. of detectors with panel can be installed in a single day even when building is occupied. Approximately 20 days are required in case of wired system. • Can be installed in running office complex / factory etc. • Complete flexibility. Any time there is a requirement for any modernization of the building. Any detector / panel can be shifted as per requirements. • Very – very competitive prices of Wireless Addressable Fire Alarm Panel. Wired panel with equal no.s of zones cost Five times more than the wireless panel. • Saving of cost from 10% to 60% at the time of installations and 90% saving in running cost. • Easy testing while every time it is practically not possible to test the system by generating smoke. A test button is available with each wireless smoke detectors and just pressing the button is sufficient for working of detector , panel and emitter. • In case of non working / failure of main control panel in wired system, whole system will be held up. But the complete system will be working in case of non working of panel. Information on location of the fire, fault and system status can be easily displayed or printed in multiple locations. Integration to voice Evacuation systems, Paging systems and third party control systems is supported through a range of peripheral interface units. Following approved makes are available - Morley –IAS, Notifier, Hochiki, GE Edward, Honeywell. Aspiration Smoke Detection System The HSSD and VESDA are the internationally approved trade names for ASPIRATION SYSTEM. Aspirating Smoke Detection system (ASD) designed to give very early indication of an incipient fire condition. This pre-emptive warning – before the transition into the flaming and heat stages – provides the time necessary to take corrective action and avoid the danger, damage and disruption to operations that a fire can cause. Aspirating Detection The detector is mounted either inside or outside the area. It draws air from the protected area using an aspirating fan which is housed in the detection unit. The pipe network contains sampling holes at predetermined locations along the pipe network through which the air is LASER DIODE LIGHT SOURCE drawn. Detectors can protect areas up to 2000 square metres to BS5839, or between 500 to 750 square metres to BS6266, in high air flow conditions. The pipework is configured in various ways according to the application. Typically it will comprise a pipe network with sampling points at intervals similar to point detection. It can also, for example, be arranged to monitor across air handling units or in ducts. Sampling pipe hart xl sampling points • Laser based particle counting – the superior technology • Elegant, compact, lightweight design • No particle filters required • No recalibration during lifetime of detector • Complete flexibility – four basic sub units provide installation options • On site sensitivity selection 0.0025%/m to 1%/m • LaserJet networking options • Modular design for fast and easy servicing • Configurable for integral or remote display options • Attachable power supply and battery back up unit • Individual pre-alarm and alarm levels Standalone Smoke Detectors Standalone smoke detectors are used for small areas such as small office, cabins, shops etc. It gives alarm from the unit in case of fire. The system consists of following • Standby Current 10 μA • Alarm Current 30 μAT • Temprature Range 10-50 oC • Alarm Density 0.65-1.55 %FT • Alarm Volume 85dB in 3meter distance • ABS Fire resistance plastic case • Unit Box 10.8x114.4cm 0.20kgs • Carton 65x24x39cm GW - 21.00kgs Beam Detection System Beam detection system is ideal where the area to be protected is large , the height of ceiling is too much and where other smoke / heat detectors will be ineffective to install. Features • Low cost protection of large areas • Very low maintenance • Quick and easy installation • Very minimum cabling required Applications • Auditorium • Multiplex • Historic Building • Warehouse • Airports • Large Storage Areas • Shopping Malls • Hotel Atria • Museums Beam Detector’s available in following brands – System Sensor, Fire Ray.

  • 2022-06-02T05:34:50

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us